Wheeler Chimney Pros

Fireplace Inspections in Hawthorne for Prefab and Masonry Fireboxes

Which Unit Do You Have?

Parts and Scope

Factory-built fireplaces carry a metal label, usually behind the screen or under the firebox floor, naming the maker, model and listing. We read it first, because it decides which panels, doors and grates are allowed. Then we check the refractory panels for cracks past the manual's limit, work the damper, test the doors and measure the trim and mantel clearances. You get a written answer on whether the unit is fit to burn.

Label read and the installation manual pulled
Refractory panels checked against the maker's crack limits
Damper handle and blade worked through full travel
Glass doors and screens checked as listed for the unit
Mantel and trim distances measured
Written verdict on whether it is fit to burn

Finding Out What Your Fireplace Is

Many owners in Hawthorne bought a house or condo with a fireplace and no paperwork. If it is factory-built, the first job of the inspection is to identify it. The label is usually a small metal plate inside the opening, on a side wall, on the smoke shelf, or tucked behind a grille at the bottom, and it names the maker, the model number and the listing the unit was tested to. With that we can find the installation manual, which is the rulebook for the unit: the clearances to wood it needs, the doors, grates and gas logs it accepts, the chimney parts that belong above it, and what the hearth in front must be made of. If the label is gone, painted over or burned off, we can often tell the maker from the panel pattern, the damper and the grille style, and we say how sure we are. A brick fireplace has no label, and we judge it against the masonry standard instead.

Once we know what the unit is, we go through it against the manual. The refractory panels are checked for cracks wider than the maker allows and for missing pieces. The damper blade, its handle and its stop are worked open and shut. The grilles and the cooling air channel are checked for blockages. The glass doors, if there are any, are checked for being the listed doors for that model. The fireproof floor in front is measured, because the manual sets how far forward and to the sides it must reach. The mantel and any trim are measured from the opening, and a wood mantel added during a remodel is one of the most common problems we write up. Above the firebox we look at the first pipe section and as much of the flue as a light shows. A Level 1 inspection like this is $54, and it covers brick fireplaces just the same.

What You Get When the Inspection Is Done

The answer comes in writing, not only at the hearth. It names the unit, or says plainly that the unit could not be identified, and lists each part we checked with one of three results: sound, worn but usable, or fix before the next fire. Each fix line carries a price or, where a part has to be sourced first, a note that the price follows once the part is found. A unit that is unsafe to light is marked that way on the first line, with the reason, so nobody misses it. For a factory-built fireplace that is past repair, the report sets out the replacement options, a new listed fireplace, a listed insert, or closing the opening off, with what each one involves. You keep the report. If you sell, it is the record a buyer's inspector will ask to see.

The usual reasons people book: the house is new to them, a home inspector flagged the fireplace, they want to start burning again after years of not using it, or they plan to add gas logs or doors and want to know whether the unit allows it. That last one matters more on factory-built units than most people expect, because a box listed for wood only is not automatically safe for a gas log set, and adding one the manual does not allow puts the whole listing at risk. When the inspection is part of a sale, or when the fireplace has been through a chimney fire, a quake or a change of fuel, a Level 2 at $385 is the right depth, since it adds a video scan of the whole flue. We tell you which level fits when you call or send the form, before anyone climbs a ladder.

How Wheeler Chimney Pros Handles the Job

Label First

Maker and model found before any quote

Listed Parts

Replacements the maker approves

Price on Paper

Each part and figure written down first

Photo Report

Each part photographed for your file

More Services

Chimney Sweep

Flue pipe and firebox cleaned with brush heads sized to the pipe, including the metal sections hidden inside a framed chase.

Parts and price →

Chimney Inspection

NFPA 211 Level 1, 2 or 3 checks for metal and masonry chimneys, picked by the reason you are calling.

Parts and price →

Chimney Repair

Chase tops, pipe sections, caps, crowns and flashing repaired with listed parts on metal systems and matched mortar on brick.

Parts and price →

Fireplace Repair

Cracked refractory panels, warped grates, broken dampers and doors on prefab fireboxes replaced with parts the maker lists.

Parts and price →

Chimney Level 2 Inspection

Video of the whole flue plus the attic and chase, booked for a sale, a quake, a chimney fire or a new appliance.

Parts and price →

Chimney Cap Installation

Rain caps for metal flues and masonry chimneys, chosen by pipe make and size, with the old cap hauled away.

Parts and price →

Chimney Flashing Repair

Water at the roof line stopped on framed chases and brick chimneys, once the real entry point is found.

Parts and price →

Chimney Masonry Repair

Brick, mortar and crown repairs for the masonry chimneys on the older houses we also service.

Parts and price →

Chimney Rebuilds

Rebuilding a framed chase, or the upper part of a brick chimney, when a repair would not hold.

Parts and price →

Fireplace Cleaning

Ash, soot and grime removed from metal and brick fireboxes, with soft refractory panels and coated glass handled gently.

Parts and price →

Gas Fireplace Cleaning

Burner, pilot, media and glass cleaned on direct-vent and B-vent gas units, plus the outdoor termination.

Parts and price →

Gas Fireplace Repair

Pilots, thermopiles, valves, igniters and remotes on gas fireplaces traced with a meter and replaced with the maker's parts.

Parts and price →

Fireplace Remodel

Surround, mantel and hearth changes on prefab fireplaces, kept inside the clearances the maker set.

Parts and price →

Fireplace Inserts

Gas inserts for masonry openings, and the listed choices for prefab boxes whose manual does not allow one.

Parts and price →

Pellet Stove Repair

Pellet stoves that will not light, feed or keep running, tested one part at a time with a meter.

Parts and price →

Wood Stove Repair

Gaskets, baffles, firebrick, glass and stovepipe on freestanding and insert wood stoves, with parts for the model.

Parts and price →

Gas Logs

Log sets for brick fireplaces and the approved log kits a prefab firebox allows, connected and leak tested.

Parts and price →

Chimney Seismic Retrofit

Quake work for tall brick chimneys: anchoring to the house, roof bracing or a lighter top, chosen after a look.

Parts and price →

Chimney Crown Repair

Cracked or crumbling crowns on brick chimneys sealed or recast; on a framed chase, the chase top does that job.

Parts and price →

Dryer Vent Cleaning

Lint cleared from the duct between the dryer and the outside hood, with the run and its fittings checked.

Parts and price →

Chimney Liner Installation

Stainless liners for brick flues, and replacement pipe for metal ones, each matched to the appliance it serves.

Parts and price →

Chimney Leak Repair

Water traced through chase tops, siding, flashing, crowns and caps, then stopped where it actually enters.

Parts and price →

Chimney Waterproofing

Breathable repellent for brick chimneys, applied once the joints and crown are in good repair.

Parts and price →

Chimney Damper Repair

Seized blades, broken handles and rusted frames on prefab and masonry dampers, repaired with the right part.

Parts and price →

Chimney Chase Cover

Rusted or dished chase tops replaced with stainless or coated covers made to the measured chase.

Parts and price →
Book a fireplace visit